A bulb base is the part that connects the lamp to its socket. For common Edison screw bases, the number identifies the nominal diameter in millimeters: E12 is 12 mm, E17 is 17 mm and E26 is 26 mm. Start with the code printed on the old bulb and the fan's lighting instructions, then check the bulb's shape, length, voltage and permitted wattage.
SCREW-BASE IDENTIFICATION
E12 | nominal 12 mm
E17 | nominal 17 mm
E26 | nominal 26 mm
Base code ≠ bulb shape
Reference dimensions · Verify the complete fitting and voltage.Guide
Read the base code before comparing bulb shapes
Look for a marking such as E12 or E26 on the bulb packaging, lamp body or fixture instructions. The letter and number describe the fitting. A separate code, such as A19, describes the bulb envelope. A19 and E26 can therefore appear on the same package: one identifies the shape and size of the glass or plastic body, while the other identifies its connection. Record both when buying a replacement for a close-fitting shade.
Guide
Use the screw-base chart
Compare the nominal diameters in the chart below after identifying an Edison screw fitting. E12 is commonly called candelabra, E17 intermediate and E26 medium. E14 and E27 may appear on products intended for other markets. Use the exact fitting and electrical requirements in the fan manual when ordering. Keep the old bulb's full marking in your notes, including its voltage, actual wattage and any dimming or enclosure suitability information.
Common screw-base sizes
Swipe the table to compare all details →
| Code | Nominal diameter | Common name | Identification check |
|---|---|---|---|
| E10 | 10 mm | Miniature screw | Match the complete fitting code. |
| E11 | 11 mm | Miniature candelabra | Distinguish from the nearby E12 size. |
| E12 | 12 mm | Candelabra | Check the bulb body as well as the base. |
| E14 | 14 mm | European screw base | Confirm the market and supply specification. |
| E17 | 17 mm | Intermediate | Match E17 in the fixture instructions. |
| E26 | 26 mm | Medium | Check voltage, actual watts and available space. |
| E39 | 39 mm | Mogul | Use only for the equipment specified for this base. |

Guide
Identify pin and twist-lock fittings separately
Two-pin and twist-lock fittings use different geometries from a screw base. For example, the numbers in GU10 and GU24 refer to pin spacing, while the E26 number describes a screw-base diameter. Photograph the connection face and copy its complete code. A bulb that has two contacts is not identified by that feature alone; the pins, spacing, locking arrangement and specified electrical supply all need to match the fixture.
Guide
Check the space inside the shade
After identifying the base, compare the proposed bulb's maximum width and overall length with the available space under the shade or cage. A larger envelope may obstruct the cover even when its base matches. Switch off the supply and allow the bulb to cool before removing it for inspection. Measure the removed bulb on a table. Use a qualified service person for a damaged socket, inaccessible fitting or any work inside the wiring enclosure.
Use a removed bulb as a dimensional reference. After safe removal under the product instructions, record the bulb's maximum body width and overall length on a table. Compare those figures with the proposed replacement's published dimensions and the fixture's available space.
Keep the base code, envelope and electrical rating as separate fields. A match in one field does not settle the others. When the shade is close-fitting or the socket is inaccessible, send the model and reference photographs to support before ordering a differently shaped bulb.
Guide
Follow a complete identification example
Example: a fan manual specifies E26 replaceable bulbs with a maximum actual input of 10 W each. The old package says A19, E26 and 8 W. Begin with E26 replacements, keep actual power at or below the manual's limit, then match the required voltage and any dimming or enclosed-fixture conditions. Finally, compare the replacement's body dimensions with the shade. The 8 W figure is the electrical input to compare with the limit; a '60 W equivalent' brightness label serves a different purpose.
Carry the example through a shortlist. Begin with candidates that match the manual's E26 fitting and required voltage. Exclude those exceeding the stated 10 W actual-input limit. Then check body dimensions, permitted enclosure conditions and compatibility with the installed control.
If two candidates pass those checks, compare lumens and CCT for the desired lighting result. Record the accepted bulb's complete model number so a future purchase can repeat the selection. This sequence keeps a familiar brightness-equivalent label from taking the place of the actual fitting and operating requirements.
Guide
Record the light-source format
Some ceiling fans use replaceable bulbs, while others use an integrated LED assembly. For a replaceable lamp, record the fitting code and each bulb's permitted power. For an integrated assembly, record the fan model and light-module reference from its service information. Keep a photograph of the complete fixture with the component photograph so the support team can identify the correct lighting arrangement.
Bulb identification record
Swipe the table to compare all details →
| Record | Example entry | Where to confirm |
|---|---|---|
| Fan model | Copy the exact model and variant | Fan label or order details |
| Base | E26 | Fixture manual and old bulb marking |
| Bulb envelope | A19; record width and length | Replacement product dimensions |
| Actual input | 8 W; manual limit 10 W per bulb | Lamp label and fixture manual |
| Supply and controls | Copy voltage and required dimming information | Fixture specification and bulb packaging |
| Shade conditions | Record cover clearance and enclosure suitability | Fixture and lamp instructions |
Frequently asked questions
Is E26 the same as A19?
E26 identifies a screw base with a nominal diameter of 26 mm. A19 describes the bulb envelope. Both codes can describe different parts of the same bulb.
Can I identify the fitting from a photograph?
A clear photograph helps distinguish a screw, pin or twist-lock fitting. Read the printed code and check the fixture manual to confirm the exact size and electrical requirements.
What should I send if the marking has worn off?
Send the fan model, a photograph of the complete light, and close-ups of the removed bulb and its base. Include any readable package or manual details.
How do I identify an integrated LED light?
Check the fan manual for an LED assembly or module reference. Use the fan's service information to identify the matching component.
Match the light to your Airsurfer fan
Keep the fan model, fitting code and bulb dimensions together. Use the lighting guide to check the remaining replacement requirements before ordering.